Electric Pump for LHL P-102/107/202/207


   Model indication method

Model Part Number Model Part Number
P-102(BK) 101002 P-202(BK) 101032
P-102(B) 101006 P-202(B) 101036
P-102F2(BK) 101082 P-207(BK) 101033
P-102F2(B) 101086 P-207(B) 101037
P-107(BK) 101003 P-202F(BK) 101042
P-107(B) 101007 P-202F(B) 101046
P-107F2(BK) 101083 P-207F(BK) 101043
P-107F2(B) 101087 P-207F(B) 101047

   Specifications

Model Part Number
Power DC24V
Power Consumption 24W
Discharge volume 7ml/min
Discharge Pressure 5MPa/8MPa
Driving Time Continuous energization
Interval Time More than 10 seconds
Wiring Method Terminal Connection
Use Cartridge LHL-X100、LHL-W100(P-207とP-207Fのみ)
Feed Switch Yes (optional)
Grease level switch Yes
Covers Flame retardant resin (UL94-V0)
IP Standard IP54
CE Approval Yes
Pump air removal No driving time restrictions
Weight P-102:1.2kg、107:1.6kg、202:1.2kg、207:1.6kg

   Model indication method

   Directions for use

  • Use manufacturer's warranty grease.
  • Never use molybdenum disulfide grease.
  • Use lithium grease. (If it is other than Lube original grease, please be sure to consult.)
  • Be careful not to mix any foreign matter when replenishing grease or replacing cartridges.
  • When replacing the cartridge, be careful not to let air enter Pump.
  • After greasing or after replacing the cartridge, be sure to open the air removal plug and remove the air inside the pump.

   Dimensional Drawing

   Wiring digram

   P type Pump Control flow